NSN: 5925-00-482-5779
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Trip Release Characteristic
time delay all locations
-
Switch Location And Position Designation
internal at pole two
-
Storage Type
general purpose warehouse
-
Mounting Surface To Terminal End Distance
2.093 inches nominal
-
Switch Voltage Rating And Type In Volts
125.0 ac and 28.0 dc
-
Reset Method
manual
-
Actuator Position Designation
at each pole
-
Thread Series Designator
unc
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.660 inches nominal
-
Pole Quantity
2
-
Circuit Protection Type
overcurrent all locations
-
Special Handling Feature
magnetic
-
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
-
Switch Terminal Type
tab, solder lug
-
Fragility Factor
moderately rugged
-
Center To Center Distance Between Terminals Parallel To Length
1.560 inches nominal
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
-
Switch Contact Arrangement
single pole, double throw
-
Unpackaged Unit Weight
5.000 ounces
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Body Style
multipole-multiple actuator type
-
Trip Release Method
magnetic-hydraulic all locations
-
Body Length
1.985 inches minimum and 2.015 inches maximum
-
Thread Quantity Per Inch
32
-
Mounting Facility Type And Quantity
4 threaded hole
-
Switch Current Rating And Type In Amps
5.0 ac and 5.0 dc
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
-
Internal Trip Release Configuration
series trip all locations
-
Actuator Function
trip-reset
-
Boss Height
0.130 inches nominal
-
Case Material
plastic
-
Maximum Continuous Load Current Rating Per Pole
24.0 amperes ac all locations
-
External Actuator Linkage Arrangement
one and two linked
-
Body Width
1.500 inches nominal
-
Auxiliary Switch Function And Quantity
1 alarm
-
Manual Actuator Type And Quantity
2 toggle
-
Terminal Type And Quantity
4 tab, solder lug
-
Frequency In Hertz
50.0 all locations or 60.0 all locations
-
Arc Quenching Method
magnetic blowout
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
-
Operating Voltage Type And Rating Per Pole In Volts
230.0 ac all locations
-
Main Contact Tripping Mechanism Type
trip free
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.150 minimum at 200 pct all locations and 1.500 maximum at 200 pct all locations
-
Nominal Thread Size
0.138 inches