NSN: 5925-00-484-3092

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac single location and 6000.0 dc single location

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Actuator Position Designation

    at pole one

  • Body Width

    0.532 inches minimum and 0.592 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    5.000 minimum at 200 pct single location and 15.000 maximum at 200 pct single location

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Mounting Surface To Terminal End Distance

    1.282 inches minimum and 1.342 inches maximum

  • Body Length

    0.720 inches minimum and 0.780 inches maximum

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Manual Actuator Type And Quantity

    1 push-pull

  • Pole Quantity

    1

  • Inclosure Protection Type For Which Designed

    explosion proof and fungus resistant

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 28.0 dc single location

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Unpackaged Unit Weight

    26.0 grams

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac single location and 20.0 amperes dc single location

  • Terminal Type And Quantity

    2 tab w/screw

  • Center To Center Distance Between Terminals Parallel To Length

    0.674 inches minimum and 0.734 inches maximum

  • Bushing Length

    0.220 inches minimum and 0.280 inches maximum

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...