NSN: 5925-00-488-9175

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Switch Terminal Type

    tab, solder lug

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Body Width

    0.750 inches nominal

  • Actuator Function

    trip-reset

  • Precious Material

    gold

  • Mounting Surface To Terminal End Distance

    1.420 inches maximum

  • Case Material

    plastic

  • Thread Series Designator

    uns

  • Switch Location And Position Designation

    internal at pole one

  • Center To Center Distance Between Terminals Parallel To Length

    0.593 inches nominal

  • Inclosure Protection Type For Which Designed

    fungus resistant and explosion proof

  • Nominal Thread Size

    0.469 inches

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Terminal Type And Quantity

    2 tab w/screw

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 30.0 dc single location

  • Switch Voltage Rating And Type In Volts

    120.0 ac and 30.0 dc

  • Switch Contact Arrangement

    single pole, single throw, normally open

  • Body Style

    single pole type

  • Frequency In Hertz

    400.0 single location

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes ac single location and 1.0 amperes dc single location

  • Body Length

    1.287 inches minimum and 1.317 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Trip Release Characteristic

    time delay single location

  • Precious Material And Location

    auxiliary terminals gold

  • Internal Trip Release Configuration

    series trip single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2500.0 ac single location and 2500.0 dc single location

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 push-pull

  • Switch Current Rating And Type In Amps

    2.0 ac and 3.0 dc

  • Trip Release Method

    thermal single location

  • Bushing Length

    0.359 inches nominal

  • Circuit Protection Type

    overcurrent single location

  • Unpackaged Unit Weight

    1.000 ounces

  • Thread Quantity Per Inch

    32

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    145.0 single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...