NSN: 5925-00-495-6519
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
-
Mounting Surface To Terminal End Distance
2.480 inches nominal
-
Manual Actuator Type And Quantity
4 toggle
-
Case Material
plastic
-
Pole Quantity
4
-
Center To Center Distance Between Terminals Parallel To Length
1.930 inches minimum and 1.950 inches maximum
-
Nominal Thread Size
0.138 inches
-
Center To Center Distance Between Terminals Parallel To Width
0.740 inches minimum and 0.760 inches maximum
-
Main Contact Tripping Mechanism Type
trip free
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.740 inches minimum and 0.760 inches maximum
-
Test Data Document
18876-11156258 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Frequency In Hertz
400.0 all locations
-
Ultimate Trip Time Per Pole In Seconds
100.000 minimum all locations and 400.000 maximum all locations
-
Body Width
3.060 inches nominal
-
Circuit Protection Type
overcurrent all locations
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Boss Height
0.150 inches nominal
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Trip Delay Time In Seconds Per Rated Continuous Current
20.000 minimum at 200 pct all locations and 80.000 maximum at 200 pct all locations
-
Internal Trip Release Configuration
series trip all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
-
Body Length
2.530 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.050 inches minimum and 2.070 inches maximum
-
Thread Quantity Per Inch
32
-
Mounting Facility Type And Quantity
8 threaded hole
-
Trip Release Method
magnetic-hydraulic all locations
-
Body Style
multipole-multiple actuator type
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
External Actuator Linkage Arrangement
one, two, three, and four linked
-
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac all locations and 50.0 amperes ac all locations and 50.0 amperes ac all locations and 100.0 milliamperes ac all locations
-
Terminal Type And Quantity
8 threaded stud