NSN: 5925-00-497-1860
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Circuit Protection Type
overcurrent single location
-
Trip Release Method
thermal single location
-
Pole Quantity
1
-
Overall Height
2.875 inches nominal
-
Nominal Thread Size
0.138 inches
-
Trip Release Characteristic
time delay single location
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2500.0 dc single location
-
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 minimum at 200 pct single location and 100.000 maximum at 200 pct single location and 3600.000 nominal at 138 pct single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
-
Reset Method
automatic
-
Operating Voltage Type And Rating Per Pole In Volts
30.0 dc single location
-
Overall Length
2.188 inches nominal
-
Thread Series Designator
unc
-
Maximum Continuous Load Current Rating Per Pole
35.0 amperes dc single location
-
Special Features
luminous tip
-
Terminal Type And Quantity
2 screw
-
Overall Width
0.750 inches nominal
-
Thread Quantity Per Inch
32