NSN: 5925-00-498-1940
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Style
1a single pole type
-
Body Width
0.562 inches nominal
-
Mounting Facility Type And Quantity
1 threaded bushing
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac single location and 5.0 amperes dc
-
Trip Release Method
thermal single location
-
Trip Release Characteristic
time delay single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 single location
-
Reset Method
manual
-
Manual Actuator Type And Quantity
1 push-pull
-
Actuator Function
trip-reset
-
Actuator Position Designation
at pole one
-
Internal Trip Release Configuration
series trip single location
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct single location and 35.000 maximum at 200 pct
-
Switch Terminal Type
tab, solder lug
-
Frequency In Hertz
60.0 single location
-
Bushing Length
0.359 inches nominal
-
Body Length
0.750 inches nominal
-
Case Material
plastic
-
Center To Center Distance Between Terminals Parallel To Length
0.593 inches nominal
-
Mounting Surface To Terminal End Distance
1.420 inches maximum
-
Pole Quantity
1
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac single location and 30.0 dc
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
800.0 ac single location and 2000.0 dc
-
Circuit Protection Type
overcurrent single location
-
Main Contact Tripping Mechanism Type
trip free
-
Auxiliary Switch Function And Quantity
1 control
-
Nominal Thread Size
0.438 inches
-
Switch Location And Position Designation
external at pole one
-
Inclosure Protection Type For Which Designed
fungus resistant
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
-
Thread Series Designator
un
-
Terminal Type And Quantity
2 screw