Technical Characteristics

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.938 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.060 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Mounting Surface To Terminal End Distance

    3.312 inches maximum

  • Mounting Facility Type And Quantity

    8 threaded hole

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes ac all locations

  • Trip Release Characteristic

    time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    3 toggle

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Switch Terminal Type

    tab, solder lug

  • Switch Voltage Rating And Type In Volts

    125.0 ac

  • Frequency In Hertz

    60.0

  • Test Data Document

    56232-338396 drawing

  • Terminal Type And Quantity

    6 threaded stud

  • Body Style

    8c multipole-multiple actuator type

  • Body Length

    2.531 inches maximum

  • Body Width

    3.000 inches nominal

  • Switch Contact Arrangement

    single pole, double throw

  • Boss Height

    0.047 inches maximum

  • Pole Quantity

    3

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic all locations

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Nominal Thread Size

    0.138 inches

  • Switch Location And Position Designation

    internal at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.250 minimum at 200 pct and 1.000 maximum at 200 pct all locations

  • Switch Current Rating And Type In Amps

    5.0 ac

  • Thread Series Designator

    unc

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...