Technical Characteristics

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Unthreaded Mounting Hole Diameter

    0.203 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    110.0 amperes ac all locations and 110.0 amperes dc all locations

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Body Height

    3.500 inches nominal

  • Body Style

    multipole-single actuator type

  • Manual Actuator Type And Quantity

    1 toggle

  • Center To Center Distance Between Terminals Parallel To Length

    6.875 inches nominal

  • Boss Height

    0.156 inches nominal

  • Frequency In Hertz

    60.0 all locations

  • Terminal Type And Quantity

    6 compression

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    25000.0 ac all locations and 1000.0 dc all locations

  • Body Length

    7.990 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    360.000 maximum at 200 pct all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.500 inches nominal

  • Case Material

    plastic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    7.125 inches nominal

  • Reset Method

    manual

  • Center To Center Distance Between Terminals Parallel To Width

    1.500 inches nominal

  • Storage Type

    general purpose warehouse

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Actuator Function

    trip-reset

  • Body Width

    4.500 inches nominal

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations and 250.0 dc all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Actuator Position Designation

    at pole two

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...