NSN: 5925-00-533-1424

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Circuit Protection Type

    overcurrent single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 ac single location and 5000.0 dc single location

  • Reset Method

    manual

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal single location

  • Body Length

    6.310 inches nominal

  • Actuator Position Designation

    at pole one

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac single location and 30.0 amperes dc single location

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Body Height

    3.380 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.190 inches nominal

  • Pole Quantity

    1

  • Mounting Slot Width

    0.188 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.880 inches nominal

  • Manual Actuator Type And Quantity

    1 toggle

  • Trip Release Method

    thermal-magnetic single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Boss Height

    0.125 inches nominal

  • Inclosure Protection Type For Which Designed

    general purpose

  • Body Style

    single pole type

  • Frequency In Hertz

    60.0 single location

  • Center To Center Distance Between Terminals Parallel To Length

    5.250 inches nominal

  • Body Width

    1.380 inches nominal

  • Terminal Type And Quantity

    2 compression

  • Trip Release Characteristic

    instantaneous single location and time delay single location

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 125.0 dc single location

  • Case Material

    plastic

  • Mounting Facility Type And Quantity

    4 slot

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.500 minimum at 200 pct single location and 10.500 maximum at 200 pct single location

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...