Technical Characteristics

  • Thread Pitch Diameters

    0.3547 to 0.3591 inches

  • Body Style

    1b multipole-single actuator type

  • Bushing Length

    0.380 inches maximum

  • Body Length

    1.500 inches maximum

  • Body Width

    1.250 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.870 inches minimum and 0.880 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.620 inches minimum and 0.630 inches maximum

  • Nonturn Device Radius

    0.620 inches minimum and 0.630 inches maximum

  • Nonturn Device Diameter

    0.245 inches minimum and 0.255 inches maximum

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes ac first location

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac first location

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc second location

  • Trip Release Characteristic

    time delay all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    between pole one and two

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.055 minimum at 200 pct all locations and 0.950 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    shock resistant and fungus resistant and hermetically sealed

  • Frequency In Hertz

    400.0 first location

  • Unpackaged Unit Weight

    100.0 grams

  • Thread Series Designator

    unef

  • Case Material

    metal

  • Nonturn Device Location

    at 3 oclock and at 9 oclock

  • Nonturn Device Length

    0.135 inches minimum and 0.145 inches maximum

  • Pole Quantity

    2

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes dc second location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac first location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc second location

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Nominal Thread Size

    0.375 inches

  • Terminal Type And Quantity

    4 wire hook

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...