NSN: 5925-00-542-6457

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Body Length

    0.750 inches nominal

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Continuous Load Current Rating Per Pole

    4.0 amperes ac single location

  • Manual Actuator Type And Quantity

    1 push button

  • Switch Current Rating And Type In Amps

    5.0 dc

  • Special Features

    push button length when closed position 0.740 inch maximum

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.438 inches

  • Unpackaged Unit Weight

    1.000 ounces

  • Body Width

    0.562 inches nominal

  • Circuit Protection Type

    overcurrent single location

  • Bushing Length

    0.359 inches nominal

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Pole Quantity

    1

  • Case Material

    metal

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Inclosure Protection Type For Which Designed

    vibration resistant and humidity proof

  • Frequency In Hertz

    400.0 single location

  • Switch Voltage Rating And Type In Volts

    28.0 dc

  • Body Style

    single pole type

  • Switch Contact Arrangement

    single pole, single throw, normally open

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 single location

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac all locations

  • Terminal Type And Quantity

    2 tab w/screw

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2500.0 ac all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct all locations and 35.000 maximum at 200 pct all locations

  • Center To Center Distance Between Terminals Parallel To Length

    0.593 inches nominal

  • Switch Location And Position Designation

    internal at pole one

  • Thread Series Designator

    uns

  • Trip Release Method

    thermal all locations

  • Mounting Surface To Terminal End Distance

    1.420 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.