NSN: 5925-00-552-5959
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Style
10b multipole-single actuator type
-
Body Width
4.750 inches nominal
-
Case Material
plastic
-
Center To Center Distance Between Terminals Parallel To Width
1.500 inches nominal
-
Unthreaded Mounting Hole Diameter
0.250 inches nominal and 0.406 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.250 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.500 inches nominal
-
Boss Height
0.312 inches nominal
-
Mounting Surface To Terminal End Distance
6.812 inches nominal
-
Mounting Facility Type And Quantity
4 unthreaded hole
-
Operating Voltage Type And Rating Per Pole In Volts
125.0 ac and 125.0 dc all locations
-
Trip Release Method
thermal-magnetic all locations
-
Trip Release Characteristic
instantaneous and time delay all locations
-
Main Contact Tripping Mechanism Type
trip free
-
Actuator Position Designation
at pole two
-
Internal Trip Release Configuration
series trip first location
-
Internal Trip Release Configuration
series trip second location
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.050 nominal at 200 pct all locations
-
Special Features
auxiliary switch connected in series w/shunt trip coil
-
Frequency In Hertz
60.0
-
Body Length
5.000 inches nominal
-
Center To Center Distance Between Terminals Parallel To Length
3.625 inches nominal
-
Switch Contact Arrangement
single pole, single throw, normally open
-
Pole Quantity
3
-
Maximum Continuous Load Current Rating Per Pole
200.0 amperes ac and 200.0 amperes dc all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
10000.0 ac and 5000.0 dc all locations
-
Circuit Protection Type
overcurrent all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0
-
Reset Method
manual
-
Manual Actuator Type And Quantity
1 toggle
-
Actuator Function
trip-reset
-
Auxiliary Switch Function And Quantity
1 control
-
Internal Trip Release Configuration
shunt trip third location
-
Terminal Type And Quantity
7 threaded stud
-
Switch Voltage Rating And Type In Volts
125.0 ac and 125.0 dc
-
Switch Current Rating And Type In Amps
10.0 ac and 10.0 dc
-
Switch Terminal Type
tab, solder lug
-
Trip Release Ambient Temp Rating
50.0 deg celsius nominal all locations
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
-
Switch Location And Position Designation
internal at pole three