NSN: 5925-00-553-9524
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Case Material
plastic
-
Pole Quantity
3
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
100.0 amperes ac and 100.0 amperes dc
-
Trip Release Characteristic
instantaneouss and time delay
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0
-
Main Contact Tripping Mechanism Type
trip free
-
Trip Delay Time In Seconds Per Rated Continuous Current
3600.000 nominal at 125 pct and 120.000 nominal at 200 pct
-
Inclosure Protection Type For Which Designed
fungus resistant
-
Frequency In Hertz
60.0
-
Terminal Type And Quantity
6 threaded stud
-
Mounting Facility Type And Quantity
4 threaded hole
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac and 250.0 dc
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac and 5000.0 dc
-
Circuit Protection Type
overcurrent
-
Trip Release Method
thermal-magnetic
-
Reset Method
manual
-
Nominal Thread Size
0.138 inches
-
Trip Release Ambient Temp Rating
25.0 deg celsius minimum
-
Thread Series Designator
unc