NSN: 5925-00-570-4643
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Reset Method
manual
-
Trip Release Characteristic
time delay all locations
-
Center To Center Distance Between Terminals Parallel To Width
0.625 inches nominal
-
Actuator Function
trip-reset
-
Body Length
2.000 inches nominal
-
Internal Trip Release Configuration
series trip all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
-
Trip Delay Time In Seconds Per Rated Continuous Current
3.000 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations
-
Trip Release Method
magnetic-hydraulic all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Actuator Position Designation
at pole two
-
Terminal Type And Quantity
3 tab, solder lug
-
Boss Height
0.125 inches maximum
-
Body Style
multipole-single actuator type
-
Manual Actuator Type And Quantity
1 toggle
-
Body Height
1.545 inches maximum
-
Main Contact Tripping Mechanism Type
trip free
-
Body Width
2.170 inches nominal
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
-
Frequency In Hertz
400.0 all locations
-
Mounting Facility Type And Quantity
1 clip
-
Maximum Continuous Load Current Rating Per Pole
2.5 amperes ac all locations
-
Case Material
plastic