NSN: 5925-00-581-6790
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac and
-
Maximum Continuous Load Current Rating Per Pole
10.0 amperes dc single location
-
Operating Voltage Type And Rating Per Pole In Volts
28.0 dc single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
-
Reset Method
manual
-
Actuator Function
trip-reset
-
Actuator Position Designation
at pole one
-
Internal Trip Release Configuration
series trip single location
-
Trip Delay Time In Seconds Per Rated Continuous Current
15.000 minimum at 200 pct and
-
Trip Delay Time In Seconds Per Rated Continuous Current
55.000 maximum at 200 pct and
-
Trip Delay Time In Seconds Per Rated Continuous Current
7.000 maximum at 400 pct single location
-
Case Material
plastic
-
Pole Quantity
1
-
Mounting Facility Type And Quantity
1 threaded bushing
-
Thread Quantity Per Inch
32
-
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac and
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3500.0 ac and
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
6000.0 dc single location
-
Circuit Protection Type
overcurrent single location
-
Trip Release Method
thermal single location
-
Trip Release Characteristic
time delay single location
-
Ultimate Trip Time Per Pole In Seconds
60.000 minimum single location
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
1 push-pull
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 400 pct and
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
-
Special Features
barrier on one side
-
Terminal Type And Quantity
2 screw