NSN: 5925-00-583-2617

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Frequency In Hertz

    400.0 all locations

  • Manual Actuator Type And Quantity

    3 push-pull

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    120.0 all locations

  • Terminal Type And Quantity

    6 tab w/screw

  • Nominal Thread Size

    0.469 inches

  • Thread Series Designator

    uns

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations and 30.0 dc all locations

  • Case Material

    plastic

  • Trip Release Method

    thermal all locations

  • Fragility Factor

    moderately rugged

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Internal Trip Release Configuration

    series trip all locations

  • Thread Quantity Per Inch

    32

  • Bushing Length

    0.250 inches nominal

  • Pole Quantity

    3

  • Mounting Surface To Terminal End Distance

    2.000 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.094 inches nominal

  • Arc Quenching Method

    air

  • Body Style

    multipole-multiple actuator type

  • Trip Delay Time In Seconds Per Rated Continuous Current

    5.000 minimum at 200 pct all locations and 15.000 maximum at 200 pct all locations

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

  • Body Length

    2.189 inches maximum

  • Body Width

    2.250 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac all locations and 10.0 amperes dc all locations

  • Mounting Facility Type And Quantity

    3 threaded bushing w/panel seal

  • Circuit Protection Type

    overcurrent all locations

  • Inclosure Protection Type For Which Designed

    shock resistant and vibration resistant

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3500.0 ac all locations and 6000.0 dc all locations

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one, two, and three linked

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...