NSN: 5925-00-590-3052

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    multipole-single actuator type

  • Body Length

    5.250 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    0.984 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.190 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.359 inches nominal

  • Boss Height

    0.218 inches nominal

  • Mounting Facility Type And Quantity

    2 unthreaded hole

  • Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes dc

  • Circuit Protection Type

    overcurrent

  • Trip Release Method

    magnetic-hydraulic

  • Trip Release Characteristic

    time delay

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Switch Location And Position Designation

    external at pole one

  • Inclosure Protection Type For Which Designed

    explosion resistant

  • Switch Terminal Type

    tab w/screw

  • Switch Current Rating And Type In Amps

    15.0 ac and 0.5 dc

  • Body Width

    2.000 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    4.359 inches nominal

  • Switch Contact Arrangement

    single pole,double throw

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    any acceptable

  • Mounting Surface To Terminal End Distance

    3.499 inches nominal

  • Pole Quantity

    2

  • Operating Voltage Type And Rating Per Pole In Volts

    28.0 dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 dc

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    between pole one and two

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Internal Trip Release Configuration

    series trip

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.170 minimum at 200 pct and 0.500 maximum at 200 pct

  • Terminal Type And Quantity

    4 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...