NSN: 5925-00-596-2146
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
~1
data on certain environmental and performanc
-
Switch Contact Arrangement
single pole, double throw
-
Body Style
multipole-single actuator type
-
Case Material
metal
-
Inclosure Protection Type For Which Designed
fungus resistant
-
Terminal Type And Quantity
4 wire hook
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Trip Release Method
magnetic all locations
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations
-
Thread Quantity Per Inch
32
-
Nominal Thread Size
0.375 inches
-
Internal Trip Release Configuration
series trip all locations
-
Mounting Surface To Terminal End Distance
1.828 inches maximum
-
Actuator Function
trip-reset
-
Center To Center Distance Between Terminals Parallel To Width
0.625 inches nominal
-
Trip Release Characteristic
time delay all locations
-
Switch Location And Position Designation
internal at pole two
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Reset Method
manual
-
Pole Quantity
2
-
Circuit Protection Type
overcurrent all locations
-
Switch Terminal Type
tab, solder lug
-
Maximum Continuous Load Current Rating Per Pole
1.0 amperes ac all locations
-
Test Data Document
81349-milc39019-4 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Body Width
1.281 inches maximum
-
Auxiliary Switch Function And Quantity
1 alarm
-
Trip Delay Time In Seconds Per Rated Continuous Current
9.000 maximum at 200 pct all locations and 0.600 maximum at 600 pct all locations and 1.750 maximum at 400 pct all locations and 0.500 minimum at 200 pct all locations and 0.100 maximum at 800 pct all locations
-
Switch Voltage Rating And Type In Volts
120.0 ac and 50.0 dc
-
Thread Series Designator
unef
-
Frequency In Hertz
400.0 all locations
-
Center To Center Distance Between Terminals Parallel To Length
0.906 inches maximum
-
Body Length
1.562 inches maximum
-
Switch Current Rating And Type In Amps
0.5 ac and 0.5 dc
-
Manual Actuator Type And Quantity
18 toggle
-
Main Contact Tripping Mechanism Type
trip free
-
Actuator Position Designation
between pole one and two
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac all locations
-
Bushing Length
0.380 inches maximum
-
External Actuator Linkage Arrangement
one and two linked
-
Ultimate Trip Time Per Pole In Seconds
3.000 minimum all locations and 60.000 maximum all locations