NSN: 5925-00-627-2011
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Mounting Surface To Terminal End Distance
1.898 inches minimum and 1.962 inches maximum
-
Internal Trip Release Configuration
series trip all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
-
Mounting Facility Type And Quantity
4 threaded hole
-
Thread Quantity Per Inch
32
-
Body Length
1.985 inches minimum and 2.015 inches maximum
-
Trip Release Method
magnetic-hydraulic all locations
-
Body Style
multipole-multiple actuator type
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Unpackaged Unit Weight
5.000 ounces
-
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac all locations
-
Boss Height
0.125 inches minimum and 0.135 inches maximum
-
Nominal Thread Size
0.138 inches
-
Inclosure Protection Type For Which Designed
humidity resistant and shock resistant and vibration resistant
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Body Width
1.468 inches minimum and 1.532 inches maximum
-
Center To Center Distance Between Terminals Parallel To Width
0.745 inches minimum and 0.755 inches maximum
-
Frequency In Hertz
50.0 all locations or 60.0 all locations
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.655 inches minimum and 1.665 inches maximum
-
Manual Actuator Type And Quantity
2 toggle
-
Terminal Type And Quantity
4 quick disconnect, male
-
External Actuator Linkage Arrangement
one and two linked
-
End Item Identification
f-16, s-3b viking, a-6e intruder aircraft. submarine acoustic sonar systems. sonar acoustic miscellaneous. h-2 seasprite, uh-1n utility/search and recovery helicopters.
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.745 inches minimum and 0.755 inches maximum
-
Case Material
plastic
-
Fragility Factor
moderately rugged
-
Circuit Protection Type
overcurrent all locations
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.500 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations
-
Pole Quantity
2
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Center To Center Distance Between Terminals Parallel To Length
1.555 inches minimum and 1.565 inches maximum
-
Storage Type
general purpose warehouse