NSN: 5925-00-642-0511

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    9.875 inches nominal

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Inclosure Protection Type For Which Designed

    shock resistant and vibration resistant

  • Precious Material And Location

    contacts silver

  • Reset Method

    manual

  • Operating Voltage Type And Rating Per Pole In Volts

    500.0 ac all locations and 250.0 dc all locations

  • Center To Center Distance Between Terminals Parallel To Length

    9.875 inches nominal

  • Precious Material

    silver

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • Arc Quenching Method

    air

  • Unthreaded Mounting Hole Diameter

    0.250 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Body Width

    9.000 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    300.000 minimum at 200 pct all locations and 900.000 maximum at 200 pct all locations

  • Body Height

    4.625 inches nominal

  • Features Provided

    adjustable trip release and interchangeable trip release

  • Actuator Position Designation

    at pole two

  • Trip Release Ambient Temp Rating

    50.0 deg celsius nominal all locations

  • Body Style

    multipole-single actuator type

  • Center To Center Distance Between Terminals Parallel To Width

    1.000 inches nominal

  • Boss Height

    0.250 inches nominal

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.000 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Body Length

    11.000 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    20000.0 ac all locations and 20000.0 dc all locations

  • Terminal Type And Quantity

    6 threaded stud and 6 tab w/screw

  • Adjustable Trip Setting Current Range Per Pole In Amps

    +650.0/+1300.0 dc all locations

  • Maximum Continuous Load Current Rating Per Pole

    250.0 amperes ac all locations and 250.0 amperes dc all locations

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...