NSN: 5925-00-655-3893

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Thread Series Designator

    unc

  • Operating Voltage Type And Rating Per Pole In Volts

    416.0 ac all locations

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Boss Height

    0.151 inches minimum and 0.161 inches maximum

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.735 inches minimum and 2.765 inches maximum

  • Thread Quantity Per Inch

    32

  • Body Width

    3.016 inches minimum and 3.046 inches maximum

  • Arc Quenching Method

    air

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.016 inches minimum and 1.046 inches maximum

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac all locations

  • Nominal Thread Size

    0.138 inches

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1500.0 ac all locations

  • Center To Center Distance Between Terminals Parallel To Width

    1.016 inches minimum and 1.046 inches maximum

  • Frequency In Hertz

    400.0 all locations

  • Body Length

    3.703 inches minimum and 3.733 inches maximum

  • Terminal Type And Quantity

    6 threaded stud

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct all locations and 30.000 maximum at 200 pct all locations

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    3.047 inches minimum and 3.077 inches maximum

  • Mounting Surface To Terminal End Distance

    2.594 inches minimum and 2.624 inches maximum

  • Manual Actuator Type And Quantity

    3 toggle

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...