Technical Characteristics

  • Body Width

    2.230 inches minimum and 2.270 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    0.735 inches minimum and 0.765 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.047 inches minimum and 2.077 inches maximum

  • Iii Storage Type

    general purpose warehouse

  • Iii Special Handling Feature

    magnetic

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    500.0 milliamperes ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Trip Release Characteristic

    time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Manual Actuator Type And Quantity

    3 toggle

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Internal Trip Release Configuration

    series trip all locations

  • Nominal Thread Size

    0.138 inches

  • Switch Location And Position Designation

    internal at pole three

  • Switch Current Rating And Type In Amps

    5.0 ac and 1.0 dc

  • Frequency In Hertz

    60.0 all locations

  • Test Data Document

    05869-711570 drawing

  • Terminal Type And Quantity

    6 threaded stud

  • Body Style

    8c multipole-multiple actuator type

  • Body Length

    2.485 inches minimum and 2.515 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.925 inches minimum and 1.955 inches maximum

  • Switch Contact Arrangement

    single pole, double throw

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.735 inches minimum and 0.765 inches maximum

  • Iii Fragility Factor

    moderately rugged

  • Boss Height

    0.125 inches minimum and 0.155 inches maximum

  • Mounting Surface To Terminal End Distance

    2.650 inches minimum and 2.800 inches maximum

  • Pole Quantity

    3

  • Iii Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic all locations

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Trip Delay Time In Seconds Per Rated Continuous Current

    3.000 minimum at 200 pct and 10.000 maximum at 200 pct all locations

  • Inclosure Protection Type For Which Designed

    shock resistant and vibration resistant and moisture resistant and salt spray proof

  • Switch Terminal Type

    tab, solder lug

  • Switch Voltage Rating And Type In Volts

    115.0 ac and 50.0 dc

  • Iii Unpackaged Unit Weight

    14.000 ounces

  • Thread Series Designator

    unc

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...