NSN: 5925-00-683-1638

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    multipole-multiple actuator type

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac all locations

  • Mounting Surface To Terminal End Distance

    3.239 inches nominal

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Boss Height

    0.156 inches nominal

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Reset Method

    manual

  • Body Width

    3.052 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Frequency In Hertz

    400.0 all locations

  • Ultimate Trip Time Per Pole In Seconds

    40.000 nominal all locations

  • Terminal Type And Quantity

    6 threaded stud

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Thread Series Designator

    unc

  • Inclosure Protection Type For Which Designed

    moisture resistant and fungus resistant and explosion resistant

  • Trip Delay Time In Seconds Per Rated Continuous Current

    25.000 nominal at 300 pct all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    416.0 ac all locations

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    3.063 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    3 toggle

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.138 inches

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1500.0 ac all locations

  • Pole Quantity

    3

  • Internal Trip Release Configuration

    series trip all locations

  • Circuit Protection Type

    overcurrent all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.031 inches nominal

  • Actuator Position Designation

    at each pole

  • Body Length

    3.719 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    1.031 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...