NSN: 5925-00-732-8549

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes ac and 1.0 amperes dc

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac and 50.0 dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac and 2000.0 dc

  • Trip Release Characteristic

    time delay

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0

  • Manual Actuator Type And Quantity

    3 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • External Actuator Linkage Arrangement

    one,two,and three linked

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.200 minimum at 200 pct and 0.900 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    shockproof

  • Frequency In Hertz

    400.0

  • Thread Series Designator

    unc

  • Body Length

    2.485 inches minimum and 2.515 inches maximum

  • Body Width

    2.235 inches minimum and 2.265 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    0.735 inches minimum and 0.765 inches maximum

  • Unthreaded Mounting Hole Diameter

    0.180 inches minimum and 0.188 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.797 inches minimum and 1.827 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.735 inches minimum and 0.765 inches maximum

  • Fragility Factor

    moderately rugged

  • Center To Center Distance Between Terminals Parallel To Length

    1.175 inches minimum and 1.205 inches maximum

  • Pole Quantity

    3

  • Storage Type

    general purpose warehouse

  • Mounting Surface To Terminal End Distance

    1.985 inches minimum and 2.015 inches maximum

  • Mounting Facility Type And Quantity

    6 threaded hole and 6 unthreaded hole

  • Special Handling Feature

    magnetic

  • Circuit Protection Type

    overcurrent

  • Trip Release Method

    magnetic

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Internal Trip Release Configuration

    series trip

  • Unpackaged Unit Weight

    0.810 pounds

  • Terminal Type And Quantity

    6 tab w/screw

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...