NSN: 5925-00-739-2240

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Quantity Per Inch

    27

  • Pole Quantity

    1

  • Internal Trip Release Configuration

    series trip single location

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct single location and 40.000 maximum at 200 pct single location

  • Inclosure Protection Type For Which Designed

    general purpose

  • Body Style

    single pole type

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac single location and 10.0 amperes dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    100.0 ac single location and 100.0 dc single location

  • Frequency In Hertz

    60.0 single location

  • Body Width

    0.570 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location and 28.0 dc single location

  • Body Length

    1.140 inches nominal

  • Unpackaged Unit Weight

    0.062 pounds

  • Center To Center Distance Between Terminals Parallel To Length

    0.780 inches nominal

  • Thread Series Designator

    uns

  • Case Material

    plastic

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    140.0 single location

  • Fragility Factor

    moderately rugged

  • Trip Release Ambient Temp Rating

    70.0 deg fahrenheit nominal single location

  • Terminal Type And Quantity

    2 pin

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Bushing Length

    0.400 inches nominal

  • Manual Actuator Type And Quantity

    1 push button

  • Nominal Thread Size

    0.375 inches

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Mounting Surface To Terminal End Distance

    2.220 inches nominal

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...