Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Thread Series Designator

    unc

  • Operating Voltage Type And Rating Per Pole In Volts

    416.0 ac all locations

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    12 threaded hole and 12 unthreaded hole

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Body Width

    4.500 inches nominal

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Body Length

    5.250 inches nominal

  • Terminal Type And Quantity

    6 threaded stud

  • Case Material

    plastic

  • Manual Actuator Type And Quantity

    3 toggle

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.600 nominal at 200 pct all locations and 0.200 nominal at 300 pct all locations

  • Unthreaded Mounting Hole Diameter

    0.190 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    4.359 inches nominal

  • Frequency In Hertz

    400.0 all locations

  • Maximum Continuous Load Current Rating Per Pole

    4.0 amperes ac all locations

  • Body Height

    2.687 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1500.0 ac all locations

  • Boss Height

    0.218 inches nominal

  • Nominal Thread Size

    0.164 inches

  • Arc Quenching Method

    magnetic blowout

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Time Per Pole In Seconds

    2.000 nominal all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.984 inches nominal

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    3.062 inches nominal

  • Body Style

    multipole-multiple actuator type

  • Trip Release Method

    magnetic all locations

  • Thread Quantity Per Inch

    32

  • Center To Center Distance Between Terminals Parallel To Width

    0.984 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...