Technical Characteristics

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1300.0 ac all locations

  • Manual Actuator Type And Quantity

    3 toggle

  • Boss Height

    0.146 inches minimum and 0.166 inches maximum

  • Precious Material And Location

    terminal surfaces silver

  • Frequency In Hertz

    400.0 all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.052 inches minimum and 2.072 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Reset Method

    manual

  • Actuator Position Designation

    at each pole

  • Operating Voltage Type And Rating Per Pole In Volts

    416.0 ac all locations

  • Thread Series Designator

    unc

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Special Handling Feature

    magnetic

  • Fragility Factor

    moderately rugged

  • Terminal Type And Quantity

    6 threaded stud

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    1.365 inches minimum and 1.385 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Nominal Thread Size

    0.138 inches

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.365 inches minimum and 1.385 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac all locations

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Mounting Surface To Terminal End Distance

    3.177 inches minimum and 3.301 inches maximum

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Body Width

    3.052 inches minimum and 3.072 inches maximum

  • Body Style

    multipole-multiple actuator type

  • Unpackaged Unit Weight

    1.000 pounds

  • Trip Release Method

    magnetic-hydraulic all locations

  • Thread Quantity Per Inch

    32

  • Trip Delay Time In Seconds Per Rated Continuous Current

    5.000 minimum at 200 pct all locations and 10.000 minimum at 200 pct all locations

  • Body Length

    3.708 inches minimum and 3.728 inches maximum

  • Internal Trip Release Configuration

    series trip all locations

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Storage Type

    general purpose warehouse

  • Precious Material

    silver

  • Center To Center Distance Between Terminals Parallel To Length

    3.052 inches minimum and 3.072 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...