Technical Characteristics
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Center To Center Distance Between Terminals Parallel To Width
0.712 inches minimum and 0.774 inches maximum
-
Inclosure Protection Type For Which Designed
shock resistant and vibration resistant
-
Thread Series Designator
unc
-
Reset Method
manual
-
Storage Type
general purpose warehouse
-
Center To Center Distance Between Terminals Parallel To Length
1.156 inches minimum and 1.218 inches maximum
-
Fragility Factor
moderately rugged
-
Internal Trip Release Configuration
series trip all locations
-
Mounting Facility Type And Quantity
4 threaded hole
-
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 minimum at 200 pct all locations and 70.000 maximum at 200 pct all locations
-
Thread Quantity Per Inch
32
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.796 inches minimum and 1.828 inches maximum
-
Manual Actuator Type And Quantity
1 push-pull
-
Actuator Position Designation
at pole two
-
Body Style
multipole-single actuator type
-
Maximum Continuous Load Current Rating Per Pole
35.0 amperes ac all locations
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal all locations
-
Nominal Thread Size
0.138 inches
-
Main Contact Tripping Mechanism Type
trip free
-
Body Height
2.125 inches maximum
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 all locations
-
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac all locations
-
Bushing Length
0.219 inches minimum and 0.281 inches maximum
-
Frequency In Hertz
400.0 all locations
-
Unpackaged Unit Weight
8.000 ounces
-
Terminal Type And Quantity
6 tab w/screw
-
Body Length
2.203 inches maximum
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2500.0 ac all locations
-
Case Material
plastic
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.470 inches minimum and 1.502 inches maximum
-
Trip Release Method
thermal all locations
-
Body Width