NSN: 5925-00-755-8279

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Actuator Function

    reset

  • Fragility Factor

    moderately rugged

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Bushing Length

    0.250 inches nominal

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Mounting Surface To Terminal End Distance

    2.218 inches maximum

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac all locations

  • Thread Quantity Per Inch

    32

  • Inclosure Protection Type For Which Designed

    vibration resistant and shock resistant

  • Body Style

    multipole-multiple actuator type

  • Unpackaged Unit Weight

    150.0 grams

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1200.0 ac all locations

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

  • Body Width

    1.218 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Delay Time In Seconds Per Rated Continuous Current

    15.000 minimum at 200 pct all locations and 55.000 maximum at 200 pct all locations

  • Mounting Facility Type And Quantity

    3 threaded bushing w/panel seal

  • Center To Center Distance Between Terminals Parallel To Length

    0.704 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 all locations

  • Manual Actuator Type And Quantity

    3 push button

  • Frequency In Hertz

    400.0 all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac all locations

  • Body Length

    2.250 inches maximum

  • Terminal Type And Quantity

    6 tab w/screw

  • Nominal Thread Size

    0.469 inches

  • Thread Series Designator

    uns

  • Case Material

    plastic

  • Trip Release Method

    thermal all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...