NSN: 5925-00-762-9961
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.100 minimum at 200 pct and 1.000 maximum at 200 pct
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal
-
Thread Series Designator
unef
-
Body Length
1.495 inches nominal
-
Case Material
metal
-
Center To Center Distance Between Terminals Parallel To Length
0.875 inches nominal
-
Center To Center Distance Between Terminals Parallel To Width
0.625 inches nominal
-
Mounting Surface To Terminal End Distance
1.678 inches nominal
-
Arc Quenching Method
magnetic blowout
-
Mounting Facility Type And Quantity
1 threaded bushing
-
Storage Type
general purpose warehouse
-
Special Handling Feature
magnetic
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
1.0 amperes ac
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 ac
-
Internal Trip Release Configuration
series trip
-
Nominal Thread Size
0.375 inches
-
Body Style
multipole-single actuator type
-
Bushing Length
0.375 inches nominal
-
Body Width
1.872 inches nominal
-
Fragility Factor
moderately rugged
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent
-
Trip Release Method
thermal
-
Trip Release Characteristic
time delay
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
130.0
-
Reset Method
manual
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
1 toggle
-
Actuator Function
trip-reset
-
Actuator Position Designation
at pole two
-
Inclosure Protection Type For Which Designed
dustproof and fungus resistant and moisture resistant
-
Frequency In Hertz
400.0
-
Terminal Type And Quantity
6 wire hook