NSN: 5925-00-774-6528

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Terminal Type And Quantity

    2 threaded stud

  • Case Material

    plastic

  • Body Width

    1.500 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    2.687 inches nominal

  • Frequency In Hertz

    60.0 single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    101.0 single location

  • Body Style

    single pole type

  • Inclosure Protection Type For Which Designed

    general purpose

  • Boss Height

    0.218 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.750 minimum at 150 pct single location and 3.000 maximum at 150 pct single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Characteristic

    time delay single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac single location

  • Internal Trip Release Configuration

    series trip single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Pole Quantity

    1

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    3.062 inches nominal

  • Circuit Protection Type

    overcurrent single location

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Body Length

    5.250 inches nominal

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Thread Series Designator

    unf

  • Reset Method

    manual

  • Mounting Surface To Terminal End Distance

    3.344 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    25.0 amperes ac single location

  • Nominal Thread Size

    0.190 inches

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac single location

  • Special Handling Feature

    magnetic

  • Trip Release Method

    magnetic single location

  • Fragility Factor

    moderately rugged

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...