NSN: 5925-00-776-1066

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.960 inches minimum and 2.160 inches maximum

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Maximum Continuous Load Current Rating Per Pole

    35.0 amperes ac

  • Operating Voltage Type And Rating Per Pole In Volts

    480.0 ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 ac

  • Circuit Protection Type

    overcurrent

  • Trip Release Method

    thermal-magnetic

  • Trip Release Characteristic

    time delay

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Auxiliary Switch Function And Quantity

    2 alarm

  • Switch Location And Position Designation

    internal at pole one and internal at pole two

  • Switch Terminal Type

    wire lead

  • Frequency In Hertz

    400.0

  • Body Length

    6.490 inches minimum and 6.510 inches maximum

  • Body Width

    4.110 inches minimum and 4.130 inches maximum

  • Body Height

    3.180 inches minimum and 3.200 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    2.740 inches minimum and 2.760 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.678 inches minimum and 0.698 inches maximum

  • Unthreaded Mounting Hole Diameter

    0.190 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.928 inches minimum and 4.948 inches maximum

  • Switch Contact Arrangement

    single pole,double throw

  • Fragility Factor

    moderately rugged

  • Boss Height

    0.300 inches minimum and 0.320 inches maximum

  • Storage Type

    general purpose warehouse

  • Special Handling Feature

    magnetic

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Position Designation

    at pole two

  • Trip Delay Time In Seconds Per Rated Continuous Current

    40.000 minimum at 200 pct and 80.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    vibration resistant and moisture resistant and shock resistant and fungus resistant and corrosion resistant

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal

  • Switch Current Rating And Type In Amps

    5.0 ac

  • Switch Voltage Rating And Type In Volts

    240.0 ac

  • Terminal Type And Quantity

    6 tab w/screw

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.