NSN: 5925-00-782-9572
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Terminal Type And Quantity
6 screw
-
Thread Series Designator
unf
-
Inclosure Protection Type For Which Designed
general purpose
-
Nominal Thread Size
0.190 inches
-
Actuator Function
trip-reset
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
-
Thread Quantity Per Inch
32
-
Mounting Facility Type And Quantity
4 threaded hole
-
Pole Quantity
3
-
Boss Height
0.218 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.359 inches nominal
-
Center To Center Distance Between Terminals Parallel To Width
1.000 inches nominal
-
Body Height
2.687 inches nominal
-
Body Length
5.250 inches nominal
-
Body Style
9b multipole-single actuator type
-
Frequency In Hertz
60.0
-
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 nominal at 130 pct all locations
-
Internal Trip Release Configuration
series trip all locations
-
Actuator Position Designation
at pole two
-
Manual Actuator Type And Quantity
1 toggle
-
Main Contact Tripping Mechanism Type
trip free
-
Reset Method
manual
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0
-
Trip Release Characteristic
time delay all locations
-
Trip Release Method
magnetic-hydraulic all locations
-
Circuit Protection Type
overcurrent all locations
-
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac all locations
-
End Item Identification
asr7
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.984 inches nominal
-
Center To Center Distance Between Terminals Parallel To Length
4.359 inches nominal
-
Case Material
plastic
-
Body Width
3.000 inches nominal