NSN: 5925-00-787-7208

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    4b multipole-single actuator type

  • Bushing Length

    0.250 inches nominal

  • Body Length

    2.203 inches maximum

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.486 inches nominal

  • Iii Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    440.0 ac all locations

  • Trip Release Characteristic

    time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    145.0 all locations

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Position Designation

    at pole two

  • Trip Release Ambient Temp Rating

    77.0 deg fahrenheit nominal all locations

  • Terminal Type And Quantity

    6 tab w/screw

  • Circuit Protection Type

    overcurrent all locations

  • Body Width

    2.250 inches maximum

  • Body Height

    2.125 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.188 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    0.743 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.812 inches nominal

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Trip Release Method

    thermal all locations

  • Manual Actuator Type And Quantity

    1 push-pull

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct and 70.000 maximum at 200 pct all locations

  • Inclosure Protection Type For Which Designed

    sand resistant and shock resistant and vibration resistant

  • Frequency In Hertz

    400.0 all locations

  • Iii Unpackaged Unit Weight

    8.000 ounces

  • Thread Series Designator

    unc

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...