NSN: 5925-00-791-8680

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Height

    2.688 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    1.000 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.359 inches nominal

  • Storage Type

    general purpose warehouse

  • Special Handling Feature

    magnetic

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac

  • Trip Release Method

    magnetic-hydraulic

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Nominal Thread Size

    0.164 inches

  • Switch Location And Position Designation

    external at pole two

  • Switch Terminal Type

    tab,solder lug

  • Switch Current Rating And Type In Amps

    15.0 ac and 0.5 dc

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    4 threaded stud

  • Body Length

    5.250 inches nominal

  • Body Width

    2.000 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    4.359 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.190 inches nominal

  • Switch Contact Arrangement

    single pole,double throw

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.000 inches nominal

  • Fragility Factor

    moderately rugged

  • Boss Height

    0.219 inches nominal

  • Pole Quantity

    2

  • Mounting Facility Type And Quantity

    4 threaded hole and 2 unthreaded hole

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac

  • Circuit Protection Type

    overcurrent

  • Trip Release Characteristic

    instantaneouss and time delay

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    between pole one and two

  • Auxiliary Switch Function And Quantity

    1 control

  • Internal Trip Release Configuration

    series trip

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.350 minimum at 200 pct and 1.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    general purpose

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 250.0 dc

  • Frequency In Hertz

    60.0

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...