NSN: 5925-00-800-4237

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Length

    2.500 inches nominal

  • Body Width

    0.750 inches nominal

  • Switch Contact Arrangement

    single pole,double throw

  • Pole Quantity

    1

  • Arc Quenching Method

    magnetic blowout

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    4.0 amperes ac

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Ultimate Trip Time Per Pole In Seconds

    18.000 minimum and 70.000 maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Internal Trip Release Configuration

    series trip

  • Nominal Thread Size

    0.138 inches

  • Inclosure Protection Type For Which Designed

    moisture resistant and fungus resistant and explosion resistant

  • Switch Terminal Type

    tab,solder lug

  • Switch Current Rating And Type In Amps

    5.0 ac and 1.0 dc

  • Frequency In Hertz

    60.0

  • Unpackaged Unit Weight

    4.250 ounces

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    2 threaded stud

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.938 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.812 inches nominal

  • Mounting Surface To Terminal End Distance

    2.611 inches nominal

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Circuit Protection Type

    overcurrent

  • Trip Release Method

    magnetic-hydraulic

  • Trip Release Characteristic

    instantaneouss and time delay

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Switch Location And Position Designation

    external at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 150 pct and 30.000 maximum at 150 pct and 4.000 minimum at 200 pct and 10.000 maximum at 200 pct and 1.400 minimum at 300 pct and 4.000 maximum at 300 pct

  • Switch Voltage Rating And Type In Volts

    125.0 ac and 50.0 dc

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.