NSN: 5925-00-805-3653

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Case Material

    plastic

  • Trip Release Method

    thermal single location

  • Circuit Protection Type

    overcurrent single location

  • Mounting Surface To Terminal End Distance

    2.000 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.796 inches minimum and 1.828 inches maximum

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Bushing Length

    0.141 inches minimum and 0.251 inches maximum

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Operating Voltage Type And Rating Per Pole In Volts

    28.0 dc single location

  • Reset Method

    manual

  • Thread Series Designator

    unc

  • Fragility Factor

    moderately rugged

  • Unpackaged Unit Weight

    0.200 pounds

  • Manual Actuator Type And Quantity

    1 push-pull

  • Main Contact Tripping Mechanism Type

    nontrip free

  • Pole Quantity

    1

  • Body Length

    2.189 inches maximum

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Maximum Continuous Load Current Rating Per Pole

    25.0 amperes dc single location

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Inclosure Protection Type For Which Designed

    explosion proof and corrosion resistant

  • Test Data Document

    81349-mil-c-7079 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Center To Center Distance Between Terminals Parallel To Length

    1.183 inches minimum and 1.193 inches maximum

  • Body Width

    0.750 inches maximum

  • Specification/Standard Data

    96906-ms24506 government standard

  • Terminal Type And Quantity

    2 tab w/screw

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Body Style

    single pole type

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct single location and 50.000 maximum at 200 pct single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3000.0 dc single location

  • ~1

    data on certain environmental and performance

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...