NSN: 5925-00-813-2094

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Bushing Length

    0.250 inches nominal

  • Thread Series Designator

    unc

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.812 inches nominal

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes dc single location

  • Actuator Function

    trip-reset

  • Inclosure Protection Type For Which Designed

    corrosion resistant and explosion proof

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Thread Quantity Per Inch

    32

  • Mounting Surface To Terminal End Distance

    2.000 inches maximum

  • Circuit Protection Type

    overcurrent single location

  • Center To Center Distance Between Terminals Parallel To Length

    1.188 inches nominal

  • Trip Release Method

    thermal single location

  • Manual Actuator Type And Quantity

    1 push-pull

  • Main Contact Tripping Mechanism Type

    nontrip free

  • Pole Quantity

    1

  • Test Data Document

    81349-mil-c-7079 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Body Length

    2.189 inches maximum

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3000.0 dc single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct single location and 50.000 maximum at 200 pct single location

  • Body Style

    single pole type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Ultimate Trip Time Per Pole In Seconds

    60.000 maximum single location

  • Terminal Type And Quantity

    2 tab w/screw

  • Specification/Standard Data

    96906-ms24506 government standard

  • Body Width

    0.750 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    30.0 dc single location

  • Case Material

    plastic

  • ~1

    data on certain environmental and performance

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...