NSN: 5925-00-822-0261

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Boss Height

    0.140 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3000.0 dc single location

  • Body Style

    single pole type

  • Trip Release Method

    magnetic-hydraulic single location

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

  • Switch Terminal Type

    tab w/screw

  • Center To Center Distance Between Terminals Parallel To Length

    1.938 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.062 inches nominal

  • Terminal Type And Quantity

    2 threaded stud

  • Body Length

    2.500 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Trip Release Characteristic

    time delay single location

  • Mounting Surface To Terminal End Distance

    2.471 inches nominal

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Inclosure Protection Type For Which Designed

    moisture resistant and fungus resistant and explosion resistant

  • Pole Quantity

    1

  • Switch Contact Arrangement

    single pole, double throw

  • Circuit Protection Type

    overcurrent single location

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Ultimate Trip Time Per Pole In Seconds

    0.700 minimum single location and 2.800 maximum single location

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes dc single location

  • Switch Voltage Rating And Type In Volts

    125.0 ac and 50.0 dc

  • Actuator Function

    trip-reset

  • Switch Current Rating And Type In Amps

    5.0 ac and 1.0 dc

  • Body Width

    0.750 inches nominal

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Operating Voltage Type And Rating Per Pole In Volts

    28.0 dc single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.170 minimum at 200 pct single location and 0.500 maximum at 200 pct single location

  • Reset Method

    manual

  • Thread Series Designator

    unc

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.