NSN: 5925-00-825-5486
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Terminal Type And Quantity
2 threaded stud
-
Operating Voltage Type And Rating Per Pole In Volts
125.0 ac single location
-
Case Material
plastic
-
Switch Location And Position Designation
internal at pole one
-
Boss Height
0.130 inches minimum and 0.150 inches maximum
-
Body Length
2.490 inches minimum and 2.510 inches maximum
-
Auxiliary Switch Function And Quantity
1 alarm
-
Frequency In Hertz
60.0 single location
-
Ultimate Trip Time Per Pole In Seconds
1.000 minimum single location and 6.000 maximum single location
-
Trip Release Method
magnetic-hydraulic single location
-
Body Style
single pole type
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac single location
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.052 inches minimum and 2.072 inches maximum
-
Arc Quenching Method
magnetic blowout
-
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac single location
-
Main Contact Tripping Mechanism Type
trip free
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Trip Release Characteristic
time delay single location
-
Nominal Thread Size
0.138 inches
-
Internal Trip Release Configuration
series trip single location
-
Manual Actuator Type And Quantity
1 toggle
-
Pole Quantity
1
-
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc
-
Switch Current Rating And Type In Amps
2.5 ac and 1.0 dc
-
Switch Contact Arrangement
single pole, double throw
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.850 maximum at 200 pct single location and 0.250 minimum at 200 pct single location and 0.090 minimum at 300 pct single location and 0.280 maximum at 300 pct single location
-
Circuit Protection Type
overcurrent single location
-
Thread Quantity Per Inch
32
-
Mounting Facility Type And Quantity
2 threaded hole
-
Body Width
0.130 inches minimum and 0.150 inches maximum
-
Actuator Function
trip-reset
-
Storage Type
general purpose warehouse
-
Actuator Position Designation
at pole one
-
Center To Center Distance Between Terminals Parallel To Length
1.928 inches minimum and 1.948 inches maximum
-
Mounting Surface To Terminal End Distance
2.461 inches minimum and 2.481 inches maximum
-
Reset Method
manual
-
Thread Series Designator
unc
-
Switch Terminal Type
tab, solder lug
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant and explosion resistant
-
Fragility Factor
moderately rugged