NSN: 5925-00-828-1363

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    12a single pole type

  • Body Length

    2.500 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.938 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.062 inches nominal

  • Iii Fragility Factor

    moderately rugged

  • Pole Quantity

    1

  • Iii Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Iii Special Handling Feature

    magnetic

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    28.0 amperes ac and 28.0 amperes dc single location

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac and 60.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    3.000 minimum at 200 pct and 25.000 maximum at 200 pct single location

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    2 threaded stud

  • Body Width

    0.750 inches nominal

  • Boss Height

    0.140 inches nominal

  • Mounting Surface To Terminal End Distance

    2.471 inches nominal

  • Iii Storage Type

    general purpose warehouse

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac and 2000.0 dc single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Reset Method

    manual

  • Internal Trip Release Configuration

    series trip single location

  • Frequency In Hertz

    60.0 single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...