NSN: 5925-00-833-7947

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Delay Time In Seconds Per Rated Continuous Current

    25.000 minimum at 200 pct single location and 150.000 maximum at 200 pct single location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.688 inches nominal

  • Case Material

    plastic

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 125.0 dc single location

  • Body Height

    3.375 inches nominal

  • Trip Release Characteristic

    instantaneous single location and time delay single location

  • Terminal Type And Quantity

    2 compression

  • Unthreaded Mounting Hole Diameter

    0.190 inches nominal

  • Frequency In Hertz

    60.0 single location

  • Body Style

    single pole type

  • Center To Center Distance Between Terminals Parallel To Length

    5.225 inches nominal

  • Inclosure Protection Type For Which Designed

    general purpose

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 single location

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Main Contact Tripping Mechanism Type

    trip free

  • Boss Height

    0.188 inches nominal

  • Trip Release Method

    thermal-magnetic single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Pole Quantity

    1

  • Body Width

    1.375 inches nominal

  • Circuit Protection Type

    overcurrent single location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.875 inches nominal

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal single location

  • Body Length

    6.312 inches nominal

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac single location and 30.0 amperes dc single location

  • Actuator Position Designation

    at pole one

  • Reset Method

    manual

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 ac single location and 5000.0 dc single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...