NSN: 5925-00-833-7948

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Actuator Function

    trip-reset

  • Body Length

    6.312 inches nominal

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.875 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    1.375 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac all locations and 20.0 amperes dc all locations

  • Body Width

    2.750 inches nominal

  • Trip Release Method

    thermal-magnetic all locations

  • Body Style

    multipole-single actuator type

  • Center To Center Distance Between Terminals Parallel To Length

    5.125 inches nominal

  • Terminal Type And Quantity

    4 compression

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Boss Height

    0.188 inches nominal

  • Actuator Position Designation

    between pole one and two

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Inclosure Protection Type For Which Designed

    general purpose

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 ac all locations and 5000.0 dc all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.375 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.190 inches nominal

  • Body Height

    3.375 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations and 250.0 dc all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    25.000 minimum at 200 pct all locations and 150.000 maximum at 200 pct all locations

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...