NSN: 5925-00-840-2090

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Bushing Length

    0.450 inches maximum

  • Body Width

    1.915 inches nominal

  • Case Material

    metal

  • Center To Center Distance Between Terminals Parallel To Length

    0.690 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    200.0 ac

  • Trip Release Method

    magnetic

  • Actuator Position Designation

    at each pole

  • External Actuator Linkage Arrangement

    one,two,and three linked

  • Internal Trip Release Configuration

    series trip

  • Nominal Thread Size

    0.375 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.000 minimum at 200 pct and 4.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    hermetically sealed

  • Unpackaged Unit Weight

    0.438 pounds

  • Thread Series Designator

    unef

  • Body Style

    multipole-multiple actuator type

  • Body Length

    1.750 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches maximum

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    1.530 inches maximum

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    3 threaded bushing

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes ac

  • Circuit Protection Type

    overcurrent

  • Trip Release Characteristic

    time delay

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    3 toggle

  • Actuator Function

    trip-reset

  • Frequency In Hertz

    400.0

  • Terminal Type And Quantity

    6 wire hook

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...