Technical Characteristics
-
Trip Delay Time In Seconds Per Rated Continuous Current
1.400 minimum at 300 pct single location and 10.000 maximum at 200 pct single location and 10.000 minimum at 150 pct single location and 4.000 minimum at 200 pct single location and 30.000 maximum at 150 pct single location and 4.000 maximum at 300 pct
-
~1
single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac single location
-
Body Style
single pole type
-
Trip Release Method
magnetic-hydraulic single location
-
Frequency In Hertz
60.0 single location
-
Auxiliary Switch Function And Quantity
1 alarm
-
Switch Location And Position Designation
internal at pole one
-
Case Material
plastic
-
Operating Voltage Type And Rating Per Pole In Volts
125.0 ac single location
-
Center To Center Distance Between Terminals Parallel To Length
1.938 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches nominal
-
Terminal Type And Quantity
2 threaded stud
-
Fragility Factor
moderately rugged
-
Switch Terminal Type
tab, solder lug
-
Thread Series Designator
unc
-
Reset Method
manual
-
Actuator Position Designation
at pole one
-
Storage Type
general purpose warehouse
-
Body Width
0.750 inches nominal
-
Switch Current Rating And Type In Amps
5.0 ac and 1.0 dc
-
Actuator Function
trip-reset
-
Switch Voltage Rating And Type In Volts
125.0 ac and 50.0 dc
-
Mounting Facility Type And Quantity
2 threaded hole
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac single location
-
Thread Quantity Per Inch
32
-
Circuit Protection Type
overcurrent single location
-
Arc Quenching Method
air
-
Mounting Surface To Terminal End Distance
2.611 inches nominal
-
Switch Contact Arrangement
single pole, double throw
-
Pole Quantity
1
-
Inclosure Protection Type For Which Designed
moisture resistant and fungus resistant and explosion resistant
-
Manual Actuator Type And Quantity
1 toggle
-
Internal Trip Release Configuration
series trip single location
-
Nominal Thread Size
0.138 inches
-
Trip Release Characteristic
time delay single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Main Contact Tripping Mechanism Type
trip free
-
Body Length
2.500 inches nominal
-
Ultimate Trip Time Per Pole In Seconds
18.000 minimum single location and 70.000 maximum single location
-
Boss Height
0.140 inches nominal