Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.735 inches minimum and 0.765 inches maximum

  • Switch Contact Arrangement

    single pole,double throw

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.047 inches minimum and 2.077 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.925 inches minimum and 1.955 inches maximum

  • Terminal Type And Quantity

    6 threaded stud

  • Thread Series Designator

    unc

  • Test Data Document

    05869-711570 drawing

  • Switch Terminal Type

    tab,solder lug

  • Trip Delay Time In Seconds Per Rated Continuous Current

    3.000 minimum at 200 pct and 10.000 maximum at 200 pct

  • Internal Trip Release Configuration

    series trip

  • External Actuator Linkage Arrangement

    one,two,and three linked

  • Trip Release Method

    magnetic

  • Circuit Protection Type

    overcurrent

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac

  • Thread Quantity Per Inch

    32

  • Special Handling Feature

    magnetic

  • Storage Type

    general purpose warehouse

  • Arc Quenching Method

    magnetic blowout

  • Mounting Surface To Terminal End Distance

    2.650 inches minimum and 2.800 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.735 inches minimum and 0.765 inches maximum

  • Case Material

    plastic

  • Body Width

    2.230 inches minimum and 2.270 inches maximum

  • Body Length

    2.485 inches minimum and 2.515 inches maximum

  • Body Style

    multipole-multiple actuator type

  • Unpackaged Unit Weight

    0.875 pounds

  • Frequency In Hertz

    400.0

  • Switch Voltage Rating And Type In Volts

    115.0 ac and 50.0 dc

  • Switch Current Rating And Type In Amps

    5.0 ac and 1.0 dc

  • Inclosure Protection Type For Which Designed

    salt spray proof and shock resistant and vibration resistant and moisture resistant

  • Switch Location And Position Designation

    internal at pole three

  • Nominal Thread Size

    0.138 inches

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Actuator Position Designation

    at each pole

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    3 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Reset Method

    manual

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Trip Release Characteristic

    time delay

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac

  • Maximum Continuous Load Current Rating Per Pole

    100.0 milliamperes ac

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Pole Quantity

    3

  • Boss Height

    0.125 inches minimum and 0.155 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...