NSN: 5925-00-849-9408

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Length

    1.938 inches nominal

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    3

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Trip Release Characteristic

    time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 third location

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • Internal Trip Release Configuration

    relay trip third location

  • Nominal Thread Size

    0.138 inches

  • Unpackaged Unit Weight

    14.000 ounces

  • Terminal Type And Quantity

    8 threaded stud

  • Body Style

    8c multipole-multiple actuator type

  • Body Length

    2.500 inches nominal

  • Body Width

    2.250 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.062 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Boss Height

    0.140 inches nominal

  • Mounting Surface To Terminal End Distance

    2.471 inches nominal

  • Special Handling Feature

    magnetic

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1500.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 first location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 second location

  • Manual Actuator Type And Quantity

    3 toggle

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip first location

  • Internal Trip Release Configuration

    series trip second location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.600 minimum at 150 pct all locations and 3.000 maximum at 150 pct and 0.200 minimum at 200 pct and 0.600 maximum at 200 pct and 0.070 minimum at 300 pct and 0.300 maximum at 300 pct

  • Frequency In Hertz

    400.0 second location

  • Frequency In Hertz

    60.0 first location

  • Frequency In Hertz

    60.0 third location

  • Thread Series Designator

    unc

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...