NSN: 5925-00-865-0177

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Pitch Diameters

    0.3503 to 0.3537 inches

  • Body Style

    2a single pole type

  • Body Length

    1.562 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.594 inches minimum and 0.656 inches maximum

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    1

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 ac single location and 300.0 dc

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Nominal Thread Size

    0.375 inches

  • Unpackaged Unit Weight

    2.100 ounces

  • Precious Material

    silver

  • Terminal Type And Quantity

    2 wire hook

  • Bushing Length

    0.370 inches minimum and 0.380 inches maximum

  • Body Width

    0.625 inches maximum

  • Case Material

    metal

  • Mounting Surface To Terminal End Distance

    1.656 inches maximum

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Special Handling Feature

    magnetic

  • Maximum Continuous Load Current Rating Per Pole

    250.0 milliamperes ac single location and 250.0 milliamperes dc

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 50.0 dc

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 single location

  • Actuator Position Designation

    at pole one

  • Internal Trip Release Configuration

    series trip single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.100 minimum at 200 pct single location and 0.600 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    fungus resistant and hermetically sealed and moisture resistant

  • Frequency In Hertz

    60.0 single location

  • Precious Material And Location

    contact surfaces silver

  • Thread Series Designator

    unef

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...