Technical Characteristics
-
Body Width
0.640 inches nominal
-
Case Material
metal
-
Center To Center Distance Between Terminals Parallel To Length
0.875 inches nominal
-
Mounting Surface To Terminal End Distance
1.605 inches nominal
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes dc single location
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc single location
-
Trip Release Method
magnetic single location
-
Trip Release Characteristic
time delay single location
-
Nominal Thread Size
0.375 inches
-
Inclosure Protection Type For Which Designed
hermetically sealed
-
Thread Series Designator
unef
-
Reference Number Differentiating Characteristics
as differentiated by special test features
-
Body Style
2a single pole type
-
Bushing Length
0.340 inches nominal
-
Body Length
1.531 inches nominal
-
Pole Quantity
1
-
Thread Quantity Per Inch
32
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 dc single location
-
Circuit Protection Type
overcurrent single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Ultimate Trip Time Per Pole In Seconds
4.000 minimum and 40.000 maximum single location
-
Reset Method
manual
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
1 toggle
-
Actuator Function
reset
-
Actuator Position Designation
at pole one
-
Internal Trip Release Configuration
series trip single location
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.600 minimum at 200 pct and 6.000 maximum at 200 pct and 0.085 minimum at 300 pct and 1.800 maximum at 300 pct and 0.015 minimum at 400 pct and 0.600 maximum at 400 pct single location
-
Special Test Features
navord od36190
-
Design Control Reference
2258974p6
-
Manufacturers Code
10001
-
Terminal Type And Quantity
2 wire hook