NSN: 5925-00-874-0954

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Quantity Per Inch

    27

  • Body Style

    multipole-single actuator type

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    6.0 ac all locations

  • Bushing Length

    0.300 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    1.560 inches nominal

  • Frequency In Hertz

    60.0 all locations

  • Body Width

    3.150 inches nominal

  • Unpackaged Unit Weight

    0.312 pounds

  • Main Contact Tripping Mechanism Type

    trip free

  • Terminal Type And Quantity

    6 screw

  • Inclosure Protection Type For Which Designed

    general purpose

  • Body Height

    2.490 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    2.320 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    500.0 ac all locations

  • Thread Series Designator

    uns

  • Case Material

    plastic

  • Trip Release Method

    thermal all locations

  • Trip Release Ambient Temp Rating

    70.0 deg fahrenheit nominal all locations

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes ac all locations

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Actuator Position Designation

    at pole two

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Nominal Thread Size

    0.375 inches

  • Manual Actuator Type And Quantity

    1 push button

  • Internal Trip Release Configuration

    series trip all locations

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Storage Type

    general purpose warehouse

  • Body Length

    1.810 inches nominal

  • Reset Method

    manual

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct all locations and 45.000 maximum at 200 pct all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...